configs/system/bus_configs.json)Validated by bus_schema.json. Describes each logical CAN bus (not how a node attaches to it).
name: Logical bus name (referenced by nodes and external nodes).baud_rate: CAN bitrate for this bus.is_extended_id: Boolean. Mixed-ID buses are not supported; all messages on a bus share this framing.is_flexible_data_rate: Boolean. Whether this bus uses CAN FD.host_fault_library: Boolean. If true, this bus is the primary uplink for fault communication (usually VCAN).busses)Validated by node_schema.json. Maps a firmware node onto hardware peripherals and message lists.
peripheral: Hardware peripheral identifier. Allowed values: CAN1, CAN2, FDCAN1, FDCAN2, FDCAN3.accept_all_messages: Boolean. If true, disables hardware filter optimization (promiscuous mode).tx: Array of TX message definitions for this node on this bus.rx: Array of RX message definitions for this node on this bus.node_name: Name of the node. Must be unique.fault_library_enabled: Required boolean. If true, this node participates in the FIDR fault sync system.faults: (Optional) Array of fault definitions specific to this node.msg_name: Unique identifier.msg_desc: Short description of message purpose.msg_priority: [0-5]. See priority convention below.msg_period: Optional. Transmission period in ms. Omit or use 0 for event-triggered (non-periodic) messages.byte_order: Optional. little_endian (default) or big_endian for multi-byte signal packing within the frame.msg_id_override: Optional. Manual ID (supports hex 0x...). Overrides automatic linking. Must respect the bus framing limits.msg_name: Name of the message to receive (must exist on the bus).callback: Boolean. If true, generates a weak-linked callback function in the driver.irq: Boolean. If true, processes the message in the RX interrupt context.sig_name: Signal name. Must be unique within the message.sig_desc: (Optional) Short description of signal purpose.type: C-type (uint8_t...double) or a custom type defined in configs/system/common_types.json.length: (Optional for standard types) Bit-length. Required for custom packing or sub-byte types.unit: (Optional) Physical unit label for DBC generation (e.g., V, Amps, C).scale: Multiplier for physical value conversion. Default 1.0.offset: Optional. Linear offset applied during physical conversion. Default 0.0.min: (Optional) Minimum theoretical value.max: (Optional) Maximum theoretical value.choices: (Optional) List of strings for enum-like labels in DBC.scale is present, unit is required by the schema.static constexpr float constants for every signal with a scale != 1.0. format: PACK_COEFF_<MSG>_<SIG> and UNPACK_COEFF_<MSG>_<SIG>. Use these to avoid magic numbers in your application code.Lower = higher priority. Range: [0-5]. PER vehicle convention:
External nodes (non-PER devices such as chargers or inverters) are defined in configs/external_nodes/ and validated by external_node_schema.json.
node_name: Name of the external device. Must be unique.bus_name: The logical bus this device sits on (must match a bus in bus_configs.json).tx: Array of messages this device sends toward PER nodes.rx: Array of messages this device expects to receive.Define reusable signal types (enums and aliases) in configs/system/common_types.json. Validated by type_registry.json.
name: Type name. Must end in _t (e.g. car_state_t).base_type: One of uint8_t ... uint64_t, int8_t ... int64_t, bool.choices: (Optional) Enum value list, generated as a C enum.Node-specific faults are defined directly in the node JSON under the "faults" key. The library automatically generates bitfield-sync and event messages for fault communication based on these definitions.
generate_fault_messages: Boolean. If true, generates LCD string arrays for the node (usually only true for nodes with displays like the Dashboard).fault_name: Unique name within the node.min: Minimum healthy value. Triggers fault if value < min.max: Maximum healthy value. Triggers fault if value >= max.priority: Impact of the fault (warning, error, fatal).time_to_latch: Time in ms the condition must persist before the fault is latched.time_to_unlatch: Time in ms the condition must be healthy before the fault is cleared.lcd_message: String text for display on the dashboard or log.