PER Firmware
|
configs/system/bus_configs.json)Validated by bus.schema.json. Describes each logical CAN bus (not how a node attaches to it).
name: Logical bus name (referenced by nodes and external nodes).baud_rate: CAN bitrate for this bus.is_extended_id: Boolean. Mixed-ID buses are not supported; all messages on a bus share this framing.is_flexible_data_rate: Boolean. Whether this bus uses CAN FD.host_fault_library: Boolean. If true, this bus is the primary uplink for fault communication (usually VCAN).busses)Validated by node.schema.json. Maps a firmware node onto hardware peripherals and message lists.
peripheral: Hardware peripheral identifier. Allowed values: CAN1, CAN2, FDCAN1, FDCAN2, FDCAN3.accept_all_messages: Boolean. If true, disables hardware filter optimization (promiscuous mode).tx: Array of TX message definitions for this node on this bus.rx: Array of RX message definitions for this node on this bus.node_name: Name of the node. Must be unique.fault_library_enabled: Required boolean. If true, this node participates in the FIDR fault sync system.faults: (Optional) Array of fault definitions specific to this node.msg_name: Unique identifier.msg_desc: Short description of message purpose.msg_priority: [0-5]. See priority convention below.msg_period: Optional. Transmission period in ms. Omit or use 0 for event-triggered (non-periodic) messages.byte_order: Optional. little_endian (default) or big_endian for multi-byte signal packing within the frame.msg_id_override: Optional. Manual ID (supports hex 0x...). Overrides automatic linking. Must respect the bus framing limits.msg_name: Name of the message to receive (must exist on the bus).callback: Boolean. If true, the generated driver declares and calls <msg_name>_CALLBACK() after RX unpacking. Application code must define this function or the firmware link will fail.sig_name: Signal name. Must be unique within the message.sig_desc: (Optional) Short description of signal purpose.type: C-type (uint8_t...float) or a custom type defined in configs/system/common_types.json.length: (Optional for standard types) Bit-length. Required for custom packing or sub-byte types.unit: (Optional) Physical unit label for DBC generation (e.g., V, Amps, C).scale: Multiplier for physical value conversion. Default 1.0.offset: Optional. Linear offset applied during physical conversion. Default 0.0.min: (Optional) Minimum theoretical value.max: (Optional) Maximum theoretical value.choices: (Optional) List of strings for enum-like labels in DBC.scale is present, unit is required by the schema.reserved, reserved1, etc. remain part of the message layout, RX data structs, and DBC output. For local TX helpers, reserved signals are omitted from the CAN_SEND_* arguments and automatically packed as zero.static constexpr float constants for every local signal with a scale != 1.0. Use PACK_COEFF_<MSG>_<SIG> before passing physical values to local CAN_SEND_* TX helpers, and use UNPACK_COEFF_<MSG>_<SIG> when interpreting raw can_data values from local RX messages.Lower = higher priority. Range: [0-5]. PER vehicle convention:
External nodes (non-PER devices such as chargers or inverters) are defined in configs/external_nodes/ and validated by external_node.schema.json.
node_name: Name of the external device. Must be unique.bus_name: The logical bus this device sits on (must match a bus in bus_configs.json).tx: Array of messages this device sends toward PER nodes.rx: Array of messages this device expects to receive.Define reusable signal types (enums and aliases) in configs/system/common_types.json. Validated by type_registry.schema.json.
name: Type name. Must end in _t (e.g. car_state_t).base_type: One of uint8_t ... uint64_t, int8_t ... int64_t, bool.choices: (Optional) Enum value list, generated as a C enum.Node-specific faults are defined directly in the node JSON under the "faults" key. The library automatically generates bitfield-sync and event messages for fault communication based on these definitions.
generate_fault_messages: Boolean. If true, generates LCD string arrays for the node (usually only true for nodes with displays like the Dashboard).fault_name: Unique name within the node.min: Minimum healthy value. Triggers fault if value < min.max: Maximum healthy value. Triggers fault if value >= max.priority: Impact of the fault (warning, error, fatal).time_to_latch: Time in ms the condition must persist before the fault is latched.time_to_unlatch: Time in ms the condition must be healthy before the fault is cleared.lcd_message: String text for display on the dashboard or log.