PER Firmware
|
peripheral: Hardware identifier (e.g., CAN1, CAN2, CAN3).accept_all_messages: Boolean. If true, disables hardware filter optimization (promiscuous mode).is_extended_id: Boolean. Set at the bus level. Mixed-ID buses are not supported; all messages on a bus will share this framing.host_fault_library: Boolean. If true, indicates this bus is the primary uplink for fault communication (usually VCAN).node_name: Name of the node. Must be unique.faults: (Optional) Array of fault definitions specific to this node.msg_name: Unique identifier.msg_desc: Short description of message purpose.msg_priority: [0-5]. See priority convention below.msg_period: Transmission frequency in ms.msg_id_override: Optional. Manual ID (supports hex 0x...). Overrides automatic linking. Must respect the bus framing limits.msg_name: Name of the message to receive (must exist on the bus).callback: Boolean. If true, generates a weak-linked callback function in the driver.irq: Boolean. If true, processes the message in the RX interrupt context.sig_name: Signal name. Must be unique within the message.sig_desc: (Optional) Short description of signal purpose.type: C-type (uint8_t...double) or a custom type defined in common_types.json.length: (Optional for standard types) Bit-length. Required for custom packing or sub-byte types.unit: (Optional) Physical unit label for DBC generation (e.g., V, Amps, C).scale: Multiplier for physical value conversion. Default 1.0.min_val: (Optional) Minimum theoretical value.max_val: (Optional) Maximum theoretical value.choices: (Optional) List of strings for enum-like labels in DBC.static constexpr float constants for every signal with a scale != 1.0. format: PACK_COEFF_<MSG>_<SIG> and UNPACK_COEFF_<MSG>_<SIG>. Use these to avoid magic numbers in your application code.Lower = higher priority. Range: [0-5]. PER vehicle convention:
Node-specific faults are defined directly in the node JSON under the "faults" key. The library automatically generates bitfield-sync and event messages for fault communication based on these definitions.
generate_fault_messages: Boolean. If true, generates LCD string arrays for the node (usually only true for nodes with displays like the Dashboard).fault_name: Unique name within the node.min: Minimum healthy value. Triggers fault if value < min.max: Maximum healthy value. Triggers fault if value >= max.priority: Impact of the fault (warning, error, fatal).time_to_latch: Time in ms the condition must persist before the fault is latched.time_to_unlatch: Time in ms the condition must be healthy before the fault is cleared.lcd_message: String text for display on the dashboard or log.